Universal Ice Maker Computer Control Board Mainboard – Flow-Type Ice Cube Machine Main Control Board – Compatible with Xingji, Xiazhixue, Xuelu, Jiujing, Inuit – Five Load Outputs – Plug and Play, No Rewiring Needed
Brief Description
Original-design universal ice maker control board, compatible with Xingji, Xiazhixue, Xuelu, Jiujing, Inuit and other flow-type ice cube machine models — plug it in and go, no rewiring needed. Onboard five outputs for hot valve / water pump / fan / water inlet valve / drain valve, with five major protections: water shortage, high temperature, high pressure, temperature sensor disconnection, and high-pressure switch disconnection. This page includes connector descriptions and a fault reference table.
Quantity
Product Overview
This board is an original-design universal ice maker main control board, compatible with Xingji, Xiazhixue, Xuelu, Jiujing, Inuit and other models. No rewiring needed — just plug it in; as long as the connectors match, it works.

Onboard Load Connectors
| Connector | Description |
|---|---|
| Heat Valve | Hot valve control output |
| Water Pump | Water pump control output |
| Cooling Fan | Condenser fan control output |
| Water Inlet Valve | Water inlet solenoid valve control output |
| Drain Valve | Drain valve control output (if equipped) |
| HP / ICEFULL / ICE S | High-pressure switch / ice-full switch / temperature probe input |



Five Major Protection Functions
- Water shortage protection: If no water enters for about 10 minutes, the machine stops automatically and the ICE, DICE and ER lights flash together
- High temperature protection: If the condenser temperature rises above about 60°C due to fan failure or similar causes, the machine stops automatically and the ICE light flashes once per second
- High pressure protection: Varies by model; some models do not have this
- Temperature sensor disconnection protection
- High-pressure switch wire disconnection protection

Operating Sequence
- On power-up, the system balances: DICE flashes, the drain valve opens (if equipped), the water pump runs, and the hot valve opens for about 30 seconds
- If there is no water, it fills automatically
- Ice making begins: after a 30-second pre-ice period, the water pump starts and the fan starts (depending on ambient temperature — it turns on above 27°C)
- Wait until the ice reaches the required thickness, then enter the ice-release state
- When the ice drops, if the baffle resets within 30 seconds, the machine automatically starts the next ice-making cycle; otherwise, if the baffle has not reset after 30 seconds, it assumes the bin is full and enters the stop state
Indicator Light Status and Fault Reference
| Status | Meaning |
|---|---|
| Water shortage protection | ICE, DICE and ER lights flash together |
| High temperature protection | ICE flashes once per second |
| High pressure protection | ER flashes once per second |
| Temperature sensor disconnection protection | ICE and ER flash once per second |
| High-pressure switch disconnection protection | ICE and DICE flash once per second |
| System balancing | DICE flashes once per second |
| DICE steady on | Ice bin full; if not full, the ice-full switch is not installed properly or is faulty |
| LD15 irregular flashing | Waiting for ice thickness (water flowing to the ice thickness sensor); steady on: ice thickness reached, waiting about 30 seconds for ice release |
| ICE steady on | Ice-making in progress |

FAQ
Q: Which ice makers is it compatible with?
A: It is compatible with Xingji, Xiazhixue, Xuelu, Jiujing, Inuit and other flow-type ice cube machine models. No rewiring needed — if the connectors match, it can be swapped in directly.
Q: Is replacement difficult?
A: Not at all. The connectors are the same as the original board, so it is plug and play. Before replacing, disconnect the power and check the position of each load plug.
Q: What protection functions does the board have?
A: It has five major protections: water shortage, high temperature, high pressure, temperature sensor disconnection, and high-pressure switch disconnection. When a fault occurs, the ICE/DICE/ER indicator lights flash to indicate it.
Q: How do I diagnose a fault?
A: You can diagnose it by the indicator light status: all three lights flashing together means water shortage, ICE flashing once per second means high temperature, and ER flashing once per second means high pressure. See the fault reference table on this page for details.